Photomultiplier Tube of High Immunity to Magnetic Fields (tetrod)
- Purpose: Scintillation irradiation detection in high energy physics under conditions of magnetic fields up to 1,2 T and radiation up to 1500 Gy.
- Year of release: 2009
- Guaranteed service life (years): 4
- Estimated production / delivery time (months): 3
- Flight qualification of the product: No
- Possibility to adapt the product to customer requirements: Yes
Parameter | Value |
---|---|
Photocathode diameter | 16 mm |
Device diameter | 22,2 mm |
Length | 46 mm |
Spectral response | 220 ÷ 650 nm |
Photocathode luminous sensitivity | ≥60 μA/lm |
Dark current | ≤2 nA |
Supply voltage | 1200 V |
Photocathode quantum efficiency (λ=420) | ≥15 % |
Photocathode | SbKCsO |
Gain under magnetic field of H=1,2T | ≥13 |
PMT-tetrode has a bialkali photocathode and two-cascade multiplication system. The input window is made of boron-silicate UV glass
Legal information
Please note that this site is for informational purposes only and under no circumstances is not a public offer determined by the provisions of the Part 2 Article 437 of the Civil code of the Russian Federation.
Information on this site may be changed or supplemented.